Search results for " Power Distribution"
showing 10 items of 47 documents
On the empirical spectral distribution for certain models related to sample covariance matrices with different correlations
2021
Given [Formula: see text], we study two classes of large random matrices of the form [Formula: see text] where for every [Formula: see text], [Formula: see text] are iid copies of a random variable [Formula: see text], [Formula: see text], [Formula: see text] are two (not necessarily independent) sets of independent random vectors having different covariance matrices and generating well concentrated bilinear forms. We consider two main asymptotic regimes as [Formula: see text]: a standard one, where [Formula: see text], and a slightly modified one, where [Formula: see text] and [Formula: see text] while [Formula: see text] for some [Formula: see text]. Assuming that vectors [Formula: see t…
Assessing fat-tailed sequential forecast distributions for the Dow-Jones index with logarithmic scoring rules
2007
We use the logarithmic scoring rule for distributions to assess a variety of fat-tailed sequential forecasting distributions for the Dow-Jones industrial stock index from 1980 to the present. The methodology applies Bruno de Finetti''s contributions to understanding how to compare the quality of different coherent forecasting distributions for the same sequence of observations, using proper scoring rules. Four different forms of forecasting distributions are compared: a mixture Normal, a mixture of convex combinations of three Normal distributions, a mixture exponential power distribution, and a mixture of a convex combination of three exponential power distributions. The mixture linear com…
Currents Distribution During a Fault in an MV Network: Methods and Measurements
2016
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighboring substations. In this paper the problem of fault current distribution is introduced, the tes…
Simple measures to improve the performances of the backward/forward method for radial distribution network analysis
2005
In the paper, after having presented the general backward/forward methodology for radial systems analysis, the main changes that have been proposed in the past to improve their convergence and speed performance are shown. Some measures aimed at a further reduction of the number of iterations and calculation times are here described. In order to identify, among the available alternatives, the best methodology, in terms of precision and/or speed of convergence, some evaluations on networks taken from the literature have been carried out. The analysis of the attained results allows the definition, on the basis of specific features of the problem at hand, the most suitable configuration to be i…
A methodology based on demand side management approaches for an optimal planning of MV-LV grid expansion in highly congested urban areas
2006
Nowadays, a renewed and growing interest is involving the Demand Side Management (DSM) techniques, since they are regarded as suitable tools in Distribution Networks planning. The following drivers trigger off this revitalisation: • The electric demand in urban contexts is growing beyond the expectations, owing to correspondingly increased needs of comfort (air-conditioning, indoor air quality, housekeeping, communication, etc.), which can be fulfilled through the electric end-uses with high quality, compliance with environmental regulations and competitive economic benefits. • This sudden higher pressure of the demand on the local Electric System is bound to force the Distributors to make …
Current transformers effects on the measurement of harmonic active power in LV and MV networks
2011
The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
A preliminary assessment of a detailed two stream short-wave narrow-band model using spectral radiation measurements
1997
Abstract A data bank of measurements of global, direct and diffuse solar spectral irradiances at ground level for clear skies has been compiled for Valencia (Spain) dating back to December 1992. The measurements were made with a commercial Li-cor 1800 spectroradiometer with a range of 300–1100 nm and a spectral resolution of 6 nm. A preliminary comparative assessment has been carried out between the experimental data and model data. The chosen model was a detailed narrow-band model (208 spectral intervals from 0.2 to 4 μm) developed at the “Laboratoire d'Optique Atmospherique (LOA)” of the University of Lille (France). This plane-parallel multilayer model uses a two-flux method to solve the…
Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion
2010
The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…
Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…